40-7705I-UM Page 86 Rev 4 March 16, 2007
11.8 Data Radio Function Group:
Figure 11-24
To access the DataRadio function group, hold down the <Alt> key and
press <D>. The Pop-up screen illustrated at above will appear. Select a
function. Proceed by selecting your target unit.
Explanation of the DataRadio Group Functions:
Function Explanation
VIEW ROUTING & STATUS
RECORDS
• Press <ALT> + <P>
• Press <V>
• Select Target Unit
This function views on the screen the Routing & Status
Records of the selected ID.
See below for an example:
PRINT ROUTING & STATUS
RECORDS
• Press <ALT> + <P>
• Press <P>
• Select Target Unit
This function prints on the printer, the Routing & Status
Records of the selected ID.
Information is similar to example below:
An illustration similar to below will appear for view. Similar information
is sent to the printer if Print is selected.
Figure 11-25
It Displays the routing record and current status of the selected Subscriber
unit.
All UL Burglar Alarm and Commercial Fire Alarm Systems require a
minimum of 2 paths.